DP_STATE=0, CHRG_DETECTED=0, PLUG_CONTACT=0, SECDET_DCP=0, DM_STATE=0
USB PHY Charger Detect Status Register
PLUG_CONTACT | Battery Charging Data Contact Detection phase output 0 (0): No USB cable attachment has been detected 1 (1): A USB cable attachment between the device and host has been detected |
CHRG_DETECTED | Battery Charging Primary Detection phase output 0 (0): Standard Downstream Port (SDP) has been detected 1 (1): Charging Port has been detected |
DM_STATE | Single ended receiver output for the USB_DM pin, from charger detection circuits. 0 (0): USB_DM pin voltage is < 0.8V 1 (1): USB_DM pin voltage is > 2.0V |
DP_STATE | Single ended receiver output for the USB_DP pin, from charger detection circuits. 0 (0): USB_DP pin voltage is < 0.8V 1 (1): USB_DP pin voltage is > 2.0V |